Sars-cov-2 /influenza a /influenza b

Disgrifiad Byr:

Mae'r pecyn hwn yn addas ar gyfer canfod ansoddol in vitro o SARS-COV-2, ffliw A ac asid niwclëig ffliw B y swab nasopharyngeal a samplau swab oropharyngeal sydd o'r bobl a oedd yn amau ​​haint SARS-COV-2, influenza a B. Gellir ei ddefnyddio hefyd mewn niwmonia a amheuir ac yr amheuir ei fod achosion clwstwr ac ar gyfer canfod ac adnabod ansoddol SARS-COV-2, ffliw A ac asid niwclëig ffliw B mewn swab nasopharyngeal a samplau swab oropharyngeal o haint coronafirws newydd mewn amgylchiadau eraill.


Manylion y Cynnyrch

Tagiau cynnyrch

Enw'r Cynnyrch

HWTS-RT148-SARS-COV-2 /influenza A /influenza B Pecyn Canfod Cyfun Niwclëig B (fflwroleuedd PCR)

Sianel

Enw'r sianel PCR-MIX 1 PCR-MIX 2
Sianel Fam Genyn orf1ab IVA
Sianel Vic/Hex Rheolaeth fewnol Rheolaeth fewnol
Sianel cy5 N genyn /
Sianel Rox E genyn IVB

Paramedrau Technegol

Storfeydd

-18 ℃

Silff-oes 12 mis
Math o sbesimen swabiau nasopharyngeal a swabiau oropharyngeal
Targedon SARS-COV-2 Tri tharged (genynnau orf1ab, n ac e) /influenza a /influenza b
Ct ≤38
CV ≤10.0%
Llety SARS-COV-2 : 300 copi/ml

Ffluenza A firws : 500 copi/ml

firws ffliw b : 500 copi/ml

Benodoldeb a) Dangosodd canlyniadau'r traws-brofion fod y pecyn yn gydnaws â sarsr- cov coronafirws dynol, mersr-cov, hcov-oc43, hcov-229e, hcov-hku1, hcov-nl63, firws syncytial anadlol 1, parainfluenza virus 1, 2 a 3, rhinovirusa, b ac c, Adenofirws 1, 2, 3, 4, 5, 7 a 55, metapneumofirws dynol, enterofirws A, B, C a D, firws pwlmonaidd cytoplasmig dynol, firws EB, firws y fair firws cytomegalofirws dynol, rotafirws, firws rotavirus, firws norovirus, firws norovirus, firws norovirus, firws norovirus, firws norovir , Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionsis, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, klebsiela pneumonium, mycobacaculosis, mycobacculosis, mycobacculosmer Glabrata Ni chafwyd unrhyw ymateb rhwng niwmocystis yersini a cryptococcus neoformans.

b) gallu gwrth -ymyrraeth: dewis mucin (60mg/ml), 10% (v/v) gwaed dynol, diphenylephrine (2mg/ml), hydroxymethylzoline (2mg/ml), sodiwm clorid (sy'n cynnwys cadwolynus) (20mg/ml),, beclomethasone (20mg/ml), dexamethasone (20mg/ml), flunisone (20μg/mL), triamcinolone acetonide (2mg/ml), budesonide (2mg/ml), mometasone (2mg/ml), fluticasone (2mg/ml), hydroclorid histamin (5mg/ml), α-internu (800i (800i (800i (800i (800i (800i (800i (800i (800IURON (800IU (800IU (800IU (800IU (800IURON (800IURON (800IURON (800IU (800IURON (800IU (800IU (800IO (800IURON (800IO (800IO (800IURON (800IO (800IU. ), Zanamivir (20mg/ml), ribavirin (10mg/ml), oseltamivir (60ng/ml), pramivir (1mg/ml), lopinavir (500mg/ml), ritonavir (60mg/ml), mupirocin (20mg/ml), azithromycin (1mhromycin (1mhromycin (1my mingromycin (1mg/ (40μg/ml) meropenem (200mg/mL), levofloxacin (10μg/mL) a tobramycin (0.6mg/mL). Dangosodd y canlyniadau nad oedd gan y sylweddau sy'n ymyrryd yn y crynodiadau uchod unrhyw ymateb ymyrraeth i ganlyniadau canfod pathogenau.

Offerynnau cymwys Biosystems Cymhwysol 7500 Systemau PCR Amser Real

Biosystems Cymhwysol 7500 Systemau PCR Amser Real Cyflym

Nglan ®-96c Systemau PCR amser real

QuantStudio ™ 5 Systemau PCR Amser Real

LightCycler®480 System PCR amser real

LineGene 9600 ynghyd â system canfod PCR amser real

Cycler Thermol Meintiol Amser Real MA-6000

BIORAD CFX96 SYSTEM PCR AMSER REAL

BIORAD CFX OPUS 96 SYSTEM PCR AMSER REAL

Cyfanswm datrysiad PCR

llif gwaith

  • Blaenorol:
  • Nesaf:

  • Ysgrifennwch eich neges yma a'i hanfon atom