12 math o bathogen anadlol
Enw'r Cynnyrch
HWTS-RT071A 12 math o becyn canfod asid niwclëig pathogen anadlol (PCR fflwroleuedd)
Sianel
Sianel | HU12Byffer ymateb a | HU12Byffer ymateb b | HU12Byffer ymateb c | HU12Byffer ymateb d |
Enw | SARS-CoV-2 | Hadv | Hpiv ⅰ | Hrv |
Vic/hecs | Rheolaeth fewnol | Rheolaeth fewnol | Hpiv ⅱ | Rheolaeth fewnol |
Cy5 | Ifv a | MP | Hpiv ⅲ | / |
Rocs | Ifv b | RSV | Hpiv ⅳ | Hmpv |
Paramedrau Technegol
Storfeydd | ≤-18 ℃ |
Silff-oes | 12 mis |
Math o sbesimen | Swab oropharyngeal |
Ct | ≤38 |
CV | ≤5.0% |
Llety | SARS-COV-2 : 300 copi/mlfirws ffliw b : 500 copi/mlFfluenza A firws : 500 copi/ml Adenofirws : 500 copi/ml mycoplasma pneumoniae : 500 copi/ml firws syncytial anadlol : 500 copi/ml, firws parainfluenza (ⅰ, ⅱ, ⅲ, ⅳ) : 500 copi/ml Rhinovirus : 500 copi/ml Metapneumofirws Dynol : 500 copi/ml |
Benodoldeb | The cross-reactivity study shows that there is no cross-reactivity between this kit and enterovirus A, B, C, D, epstein-barr virus, measles virus, human cytomegalovirus, rotavirus, norovirus, mumps virus, varicella-herpes zoster virus, Bordetella pertussis, Streptococcus pyogenes, mycobacterium Twbercwlosis, Aspergillus fumigatus, Candida albicans, Candida glabrata, niwmocystis jirovecii, cryptococcus neoformans ac asid niwclëig genomig dynol. |
Offerynnau cymwys | Biosystems Cymhwysol 7500 Systemau PCR Amser RealBiosystems Cymhwysol 7500 Systemau PCR Amser Real CyflymQuantStudio®5 system PCR amser real Systemau PCR amser real SLAN-96P (Hongshi Medical Technology Co., Ltd.) LightCycler®480 System PCR amser real, LineGene 9600 ynghyd â System Canfod PCR Amser Real (FQD-96A , Technoleg Bioer Hangzhou) MA-6000 Cycler Thermol Meintiol Amser Real (Suzhou Molarray Co., Ltd.) BIORAD CFX96 SYSTEM PCR AMSER REAL BIORAD CFX OPUS 96 SYSTEM PCR AMSER REAL |
Llif gwaith
Opsiwn 1.
Adweithydd echdynnu a argymhellir: Adweithydd Rhyddhau Sampl Macro a Micro-brawf (HWTS-3005-8) gan Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Dylai'r echdynnu gael ei wneud yn unol â'r cyfarwyddiadau.
Opsiwn 2.
Ymweithredydd Echdynnu a Argymhellir: Pecyn DNA Cyffredinol Macro a Micro-Brawf (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) a macro a micro-brawf echdynnu asid niwclëig awtomatig ( HWTS-3006C, HWTS-3006B) gan Jiangsu Macro & Micro-Test Dylid cynnal Med-Tech Co., Ltd., yr echdynnu yn unol â'r cyfarwyddiadau yn llym. Y cyfaint elution a argymhellir yw 80μl.
Opsiwn 3.
Ymweithredydd echdynnu a argymhellir: Pecyn echdynnu neu buro asid niwclëig (YDP315) gan Tiangen Biotech (Beijing) Co., Ltd., Dylai'r echdynnu gael ei gynnal yn unol â'r cyfarwyddiadau yn llym. Y cyfaint elution a argymhellir yw 100μl.